井冈山电厂#2机组节能降耗分析与实施

正文:
井冈山电厂#2机组节能降耗分析与实施

井冈山电厂#2机组节能降耗分析与实施

摘要:井冈山电厂#2机组2001年投产运行,2011年1月由西安热工院进行了#2机组性能诊断试验,结果试验热耗为8370 KJ/Kwh,比设定值高440 KJ/Kwh,#2汽机本体存在高压缸效率低、高排温度高、高中压缸内外缸出现变形、高进平衡环汽封套变形等现象,为了降低机组热耗,2011年3月对#2机组汽轮机本体进行检修,以消除缺陷,降低热耗。

关键词:井冈山电厂 , 检修,降低,热耗

Abstract: the jinggang mountains power plant # 2 unit was run in 2001, and in January 2011, the thermal construction courtyard carried on # 2 unit performance diagnosis, the test test the heat consumption for 8370 KJ/Kwh, high value than 440 KJ/Kwh, # 2 turbine high pressure cylinder ontology being low efficiency, high temperature high pressure, high school row inside and outside cylinder cylinder deformation, high into balance in steam covers the phenomenon such as deformation ring, in order to reduce the heat consumption unit, and in March 2011 to # 2 turbine generating unit overhaul the ontology, in order to eliminate the defects, lower the heat consumption.

Key words: the jinggang mountains in power plant, maintenance, lower, the heat consumption

中图分类号: TM62文献标识码:A文章编号:

1前言

目前,煤炭资源紧张情况下,提高热效率成为各大电厂共同的检修目标,节能降耗是汽轮机组检修的重要指标,很多厂家对检修后的汽轮机热耗值提出考核指标,为了更广阔的检修市场,提高检修质量,提高机组效率,降低热耗,实现业主机组检修的目的,否则,就会失去市场;同样,实现节能降耗是我们进行汽轮机组检修水平的体现。

2机组概况

井冈山电厂#2机组为为哈汽73A型亚临界一次中间再热300MW机组,汽轮机为国产引进技术生产的300MW亚临界、中间再热、单轴、双缸、双排汽、凝汽式汽轮机。本机组属反动式汽轮机,热力级有28级(结构级36级),与1025t/h亚临界、中间再热、自然循环汽包式锅炉及300MW水氢氢冷却发电机配套。